Xinjiang Hesheng Silicon Industry Fan Room Acoustic Enclosure Case Study


Project Overview

This industrial fan room acoustic enclosure noise reduction project was completed for Hesheng Silicon Industry in Xinjiang. High-power fans inside the plant generate strong continuous aerodynamic noise, affecting workshop working environment. We delivered a full fan room sound enclosure solution, including acoustic panel fabrication, acoustic louver design, steel frame assembly and on-site installation. The industrial acoustic enclosure controls noise while ensuring air circulation for fan operation.


 


Noise Sources & Challenges

Main noise sources:

· Fan blade aerodynamic noise

· Motor mechanical vibration noise

· Airflow regeneration noise

Project challenges: The fan acoustic hood must maintain sufficient ventilation via acoustic louvers to prevent fan overheating. The enclosure structure needs strong wind resistance and anti-dust performance to adapt to Xinjiang dry and dusty climate.


 


Custom Acoustic Enclosure Solution

Sound Absorption & Insulation Panels

Sandwich composite acoustic panels absorb and isolate industrial low & medium frequency noise. Acoustic louvers are installed for ventilation.

Heavy-Duty Steel Support Frame

Sturdy steel frame with anti-corrosion coating, stable for long-term industrial workshop operation.



 


Key Specifications

· Noise reduction: 18–25dB(A), meets factory occupational noise standards

· Acoustic louver ventilation, no impact on fan performance

· Dust-proof, wind-resistant for harsh inland industrial environment

· Removable access door for equipment maintenance



 




On-Site Installation

The modular fan room acoustic enclosure fully encloses the fan unit inside the factory workshop. Acoustic louvers provide air intake and exhaust, forming a closed noise isolation room.






 


Project Results

✅ Noise control: Industrial fan acoustic enclosure reduces noise inside workshop and improves working environment.

✅ Stable fan operation: Ventilation louvers guarantee proper airflow and prevent overheating.

✅ Durable structure: Anti-dust & anti-corrosion frame adapts to Xinjiang harsh climate.

✅ Convenient maintenance: Access door enables easy inspection and overhaul.



02

Certificates

Certificates Certificates Certificates Certificates >Certificates